Wind charge controller 4 kW – 48 V
SKU: 15911
Delivery: 14 to 18 days
- Secure payment
- 14-day returns
- Tracked shipping
This wind charge controller is intended for installations on 48 V DC batteries. It manages a nominal input power of 4 kW, with a maximum of 5 kW, and includes an LCD display, electrical protections, and automatic electromagnetic braking.
- Manages a nominal input power of 4 kW, up to a maximum of 5 kW.
- Displays current, power, and battery voltage on LCD screen.
- Integrates protections against lightning, overloads, deep discharge, short circuits, and polarity reversal.
- Triggers automatic electromagnetic braking from 58 V or when the temperature reaches 50 °C.
- Features a manual shutdown switch for maintenance operations.
- Nominal battery voltage: 48 V DC
- Minimum battery voltage: 42 V
- Nominal input power: 4 kW
- Maximum input power: 5 kW
- Maximum wind charge current: 70 A
- Charge voltage: 52.8 V
- Automatic braking: Electromagnetic braking by short-circuiting from 58 V or at 50 °C; reset at 45 °C
- Required dump load resistor: External 4 kW resistor
- Display: LCD screen: current, power, and battery voltage
- Connections: Screw terminals for 10 mm² cables
- Protection index: IP20, indoor use
- Cooling: External aluminum fins
Charge management for 48 V battery
The regulator operates with a nominal battery voltage of 48 V DC, for a minimum indicated voltage of 42 V. The maximum wind charge current is 70 A and the charge voltage is 52.8 V.
The charge is controlled by a microprocessor with voltage and current limitation.
Braking and load shedding
Automatic braking is performed by electromagnetic short-circuiting. It activates from 58 V or at 50 °C for the cooling system, with reset at 45 °C.
The operation includes an external load shedding resistor of 4 kW. Three load shedding resistors are activated successively for five seconds each during interval braking.
Protection and connection
The screw terminals accept cables of 10 mm². The enclosure has external aluminum cooling fins.
With its IP20 rating, this regulator is designed for indoor use.
Integration into a hybrid installation
This model is not a hybrid regulator. It can be integrated into a hybrid system with a battery bank and compatible equipment.
A solar regulator and a wind regulator can be connected in parallel to the same battery bank.
Compatible with
- Can be integrated into a hybrid system using a battery bank and compatible equipment.
- Can be connected in parallel with a solar regulator on the same battery bank.
Compatibility limits
- This regulator is not a hybrid model.
- Intended for indoor use in accordance with IP20 rating.
Precautions
- The external load shedding resistor must be installed horizontally to function effectively.
What battery voltage is intended for this regulator?
It is designed for a 48 V DC battery, with a minimum indicated voltage of 42 V.
What wind power can it handle?
The nominal input power is 4 kW and the maximum input power is 5 kW.
How does the automatic braking work?
Electromagnetic braking by short-circuiting occurs from 58 V or when the cooling system reaches 50 °C. Resetting is indicated at 45 °C.
Does the dump load resistor need to be in a specific position?
Yes. The dump load resistor must be placed horizontally.
Can it be connected to a solar regulator?
Yes, a solar regulator and a wind regulator can be connected in parallel to the same battery bank.