FAQ · Wind and Solar
Hybrid: grid self-consumption
Addition of an independent wind chain, single-phase or three-phase injection, and self-consumption uses.

Choose a question to display its answer. For any compatibility or electrical intervention, check the manual of each equipment and the complete characteristics of the installation.
Add a wind chain in parallel with solar
Add 230V wind turbine to my solar installation without disrupting production?
A wind kit with its dedicated inverter can be added on the grid side, subject to compatibility and electrical validation. Check the cumulative power, surplus management, protections, and coupling conditions of the solar installation; absence of disruption cannot be guaranteed based on a simple description. Resources: 230 V Kits.
Add a 1500W wind kit to 2 photovoltaic installations?
Yes, a wind injection kit can connect in parallel with an existing solar installation, provided a compatible architecture. Consult 230 V grid kits.
Wind/solar self-consumption: can you contact me for a kit (wind turbine + inverter)?
To get guidance, use the contact form specifying the wind measured at the future rotor, the available space for the mast, and the single-phase or three-phase network. Compare the published kits and their composition; no response time or phone call should be assumed from this FAQ. Resources: 230 V self-consumption wind turbine kits · contact form.
How to add a wind turbine to a photovoltaic installation already equipped with a 10kW inverter?
A wind turbine supplement can use an independent wind inverter on the AC side. Its compatibility with the existing photovoltaic installation must be validated: network, cumulative power, circuits, protections, anti-islanding, and surplus management. Do not connect the wind turbine to the PV input and do not assume the absence of interaction between the systems. Resources: Self-consumption wind turbine kits.
How to install a grid-tie wind inverter?
Connect only a generator explicitly compatible with the wind input of the inverter, according to its manual. A solar input only receives the intended photovoltaic sources. The grid output must connect to a circuit sized and protected for the device, with validation of the connection and anti-islanding; do not transpose a universal connection to a 16 A socket. Resources: grid kits.
Do I need to buy a separate MPPT controller with a wind kit that already includes the wind turbine and grid inverter?
If the kit already includes the necessary electronics for direct injection and a validated protection device, do not add an unplanned intermediate controller. Check the exact composition in the manual. A solar MPPT does not replace wind regulation and should not be inserted between the generator and the wind inverter. Learn more: ERDF self-consumption wind turbine kits 230V/230V.
Vertical wind turbine 230V plug & play: technician or installation?
We do not have technicians for installation. For self-consumption, a wind turbine is connected via a special wind inverter (and not a solar micro-inverter "plug & play"). You will find ready-to-inject sets and diagrams here: 230 V wind grid kits • 230 V wind injection inverters • connection diagrams.
Wind kit on domestic socket with existing solar installation: possible without risk?
A network-side coupling may be possible if each source uses its compatible inverter and if the cumulative power, circuits, and protections are validated. No setup is "risk-free" by principle. Have the coupling rules, surplus management, and anti-islanding verified for exact references. Resources: 230 V wind grid kits · injection inverters.
Solar kit 700W + small self-consumption wind turbine: compatible?
Yes, in parallel on the domestic network: the solar injects via a micro-inverter, and the wind via a special wind inverter (3-wire AC input) or a dedicated kit. Both productions combine to cover your uses. See 230 V wind grid kits. The final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections.
Does adding a wind turbine disrupt my solar system?
The sources use separate inverters, but their coexistence must be verified for the installation: cumulative power, single or three-phase networks, circuit limits, protections, surplus management, and anti-islanding. An absence of disruption cannot be guaranteed without this validation. Learn more: Hybrid wind + solar kits.
Can my 230V self-consumption solar installation accommodate a wind turbine?
A solar installation can receive an independent wind chain on the AC side if the coupling is explicitly compatible and correctly sized. Have the circuits, protections, cumulative power, anti-islanding, and surplus management verified. The wind turbine should not be connected to the solar PV inputs. Learn more: Self-consumption hybrid kits.
A schematic for connecting the generator to the 230V inverter?
Consult our connection diagrams (wind/solar/hydro, protections, cable sections, 230 V connection) here: Connection diagrams.
Can a self-consumption wind turbine operate in parallel with solar panels and an EcoFlow system?
A network-side coupling may be feasible if each source uses its compatible inverter and if the EcoFlow itself is installed in a mode allowing this architecture. The wind turbine does not directly charge the EcoFlow battery. Have the coupling rules, surplus management, anti-islanding, and power limits checked by EcoFlow and an electrician. Learn more: ERDF wind kits for self-consumption 230V/230V.
Is a 500W wind kit compatible with a 230V / 50Hz network and a photovoltaic installation?
Only if it is a self-consumption kit explicitly designed for the 230V / 50Hz network and includes electronics compatible with the generator. Solar and wind use separate inverters. Check anti-islanding, protections, the cumulative power of the circuit, and the single-phase or three-phase network. The exact reference of the kit must be checked on its datasheet. Learn more: ERDF wind kits for self-consumption 230V/230V.
Can a Vector 350W wind turbine be added in parallel to a Beem solar kit?
The two productions can coexist on the network side only if the wind turbine is part of a self-consumption set explicitly compatible with its own wind inverter. It must not be connected to the micro-inverter or solar inputs of the Beem kit. Have the cumulative power, line, protections, anti-islanding, and applicable procedures checked. The compatibility of the Vector 350W must be confirmed on its exact datasheet. Learn more: ERDF wind kits for self-consumption 230V/230V.
Add wind kit to my solar panels?
Yes, with a validated architecture. On the network side, each source uses its dedicated inverter. In an isolated site, each source retains its regulation and only joins the same array if the voltages, charge profiles, currents, and BMS requirements are compatible. Do not connect the wind turbine to a PV input. Learn more: Hybrid kits for isolated sites.
Also inject into the 230V network in parallel with panels: options for the wind turbine?
Two ways: (1) via your batteries (the hybrid inverter injects the surplus); (2) via a dedicated wind network injection inverter, connected to 230 V in parallel with your solar installation (the special wind inverter manages the 3-wire AC input). See wind network injection inverters 230 V and wind network kits.
Tulip wind turbine: plug-and-play with inverter?
No. Tulip wind turbines deliver variable AC (3 wires) and require a regulator with brake/dump-load to charge a battery array; they do not connect to a plug & play micro-inverter like panels. In practice, a hybrid system (solar + wind) is built around the batteries, then converted to 230 V via an adapted inverter. See: hybrid wind regulators and hybrid kits (isolated site).
Should an external MPPT regulator be added between an Air-WPR 24V / 800W and a special wind inverter?
Do not add a solar MPPT between the Air-WPR and a wind inverter. If the association of references is explicitly validated for direct injection, follow its manual and the prescribed braking or dump-load functions. Intermediate regulation is only necessary if the system's design requires it; it is not chosen by analogy with solar. Learn more: Wind network injection inverters 230V.
Is the Pro Air-Side 2000W 48V / 230V (self-consumption) kit compatible with solar panels in an isolated site?
No. This model is designed for direct injection into the 230 V network (self-consumption) and is not compatible with a solar system in an isolated site. The final compatibility must be checked on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections. Learn more: Hybrid kits for isolated sites.
Can I connect a wind turbine to a 230V outlet for my solar hybrid inverter to manage its production?
Not with a wind turbine intended for charging a 48 V battery array. In this configuration, the wind turbine does not connect to a 230 V outlet: it charges the batteries via an adapted wind regulator. The hybrid inverter then uses the available energy in the battery array to power the installation. A connection to a 230 V outlet corresponds to a network self-consumption architecture equipped with a specific wind inverter. It must not be mixed with an existing solar installation without explicitly validated compatibility and synchronization. The final compatibility must be checked on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections. Learn more: ERDF wind kits for self-consumption 230V/230V.
Can I inject into the network through 12V batteries with a domestic wind turbine?
Yes. Typical chain: Wind turbine (3-wire AC) → 12 V wind regulator with dump-load → 12 V battery array → 230 V "storage" injection inverter accepting a 12 V battery input. Do not connect the wind turbine to a PV/MPPT solar input. See wind regulators and network injection inverters. The final compatibility must be checked on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections.
Which kit do you recommend for a simple self-consumption 230V installation (without battery)?
Examine the published kits for 230 V self-consumption with explicitly compatible generator and inverter. Check the composition, protections, and authorized connection in the manual. A dedicated outlet or circuit must be sized for the device and installation; do not assume all kits connect the same way or coexist without validation with solar. Resources: 230 V self-consumption wind kits.
What are the advantages of a 230V hybrid inverter?
A hybrid inverter can combine several functions depending on the model: conversion, battery charging, PV management, and possibly backup. A wind turbine maintains dedicated regulation and does not connect to a PV input. Continuity in case of an outage requires an explicitly documented backup function, a compatible park, and validated wiring. Resources: hybrid inverters.
What are the advantages of a plug and play wind + solar hybrid system?
Solar and wind sources can complement each other by diversifying production periods if the local resource allows. Without a battery and with injection inverters, the grid remains necessary; this does not provide autonomy or guaranteed power in case of an outage. Check the coupling and protections of each chain. Resources: grid kits.
Can an AeroSpiral 1500W be directly connected to a photovoltaic self-consumption installation without batteries?
No. The currently offered AeroSpiral models are designed for battery charging. They should not be directly connected to the photovoltaic input of a solar inverter nor used without a battery park. The setup must include a wind regulator and batteries of the same nominal voltage. Learn more: AeroSpiral UWT vertical wind turbines – Silent alternative to the liam f1 wind turbine for 24V / 48V batteries.
Three-phase network and existing installations
Self-consumption with three-phase Linky and 1800 Wc PV: I want to add a vertical wind turbine ≈1500W, what are the options in three-phase?
Our direct injection verticals are mainly in 230 V single-phase. In three-phase, either prioritize a 380/400 V three-phase inverter (with compatible generator) or three single-phase paths distributed per phase for balancing. See 380/400 V three-phase inverters.
Which solar solution to choose to complement a three-phase self-consumption wind installation (230 / 400V)?
Two common approaches: 1) Direct three-phase 230/400V setup (solar kit designed for three-phase grid, often with storage) → Solar grid kits 2) 1 inverter per phase (3 inverters in total) → 230V solar grid injection inverters
A 400V three-phase hybrid inverter with 48V batteries: options to add a wind turbine?
Two options: • Three-phase grid injection → three-phase self-consumption wind kit • Autonomy / 48V batteries → 48V wind turbine in battery charging + regulator Learn more: Hybrid kits for isolated sites.
Prioritize the water heater in self-consumption
Self-consumption: how to prioritize the 230V water heater with my solar + wind without modifying the regulators?
Inject your sources on the 230 V and control the tank with a contactor/programmer (windy/sunny hours). This control is on the AC side, separate from the wind dump-load. Useful equipment: relays & contactors. Wiring diagrams: wiring diagrams.
230V electric water heater: what simple solution with my solar + wind in domestic self-consumption?
The simplest is to inject each source into your domestic 230 V grid (PV inverter on the solar side, special wind inverter on the turbine side). The water heater remains a standard AC use, powered primarily by your instantaneous production. See 230 V wind injection inverters and solar grid kits.
Need advice on a reference?
Specify the relevant references and the characteristics of your installation to customer service.