45V per phase on three-phase output: normal?
Specify if the 45 V are measured between two phases or between a phase and a neutral, as well as the type of multimeter and the rotation regime. The voltage varies with speed and load. For a sinusoid, 45 V effective corresponds to about 64 V peak for the same measurement; this does not constitute an available DC voltage nor a validation of inverter compatibility. Have the measurements performed according to the manufacturer's safety procedure. Learn more: Measurement tools.
How to know the wind strength and estimate production?
Measure the average speed over 6–12 months with an anemometer and avoid turbulence zones. Tools & methods: measurement tools • estimation methods.
Accessories to optimize energy production?
Yes: MPPT regulators, 230 V hybrid inverters, DC/DC converters, programmers, and meters. Browse: hybrid inverters • meters.
Lighting and consumption: what to choose?
Are the measurement tools suitable for outdoor use?
Yes, several instruments (anemometers, lux meters, certain meters) are designed for outdoor use. Check the IP rating, temperature range, and power supply before use. Selection: Measurement tools.
Does Linky automatically balance the phases?
No. The meter does not distribute the production from one phase to the others. Learn more: Electric meter.
Used/obsolete weather instrumentation equipment for practical work (BTS Maintenance)?
No, we only sell new equipment. For on-site measurement, you can consult our current solutions (meters/electrical measurements): measurement tools.
My site assumptions indicate 2,000 hours/year of sunshine and 26m/s average wind: is this consistent?
For reference, 26 m/s ≈ 93.6 km/h — a very high value for an average. It is likely a gust or a maximum. We recommend verifying the data with on-site measurements before sizing. Tools and principles: measurement tools and wiring diagrams.
Why is the calculation only valid for sinusoidal currents?
The formula assumes pure sinusoids. With harmonics (e.g., frequency converter), the overall power factor (phase shift + distortion) changes; RMS measurements and the total PF must then be used. More info: Advice & information.
Can I order accessories for renewable energies?
Yes, a wide choice of accessories: masts, mounts, regulators, inverters, meters, cables… See: masts & mounts • regulators • inverters. Final compatibility must be checked on exact references: nominal voltage, input or output type, admissible power, regulation, and protections.
What does the efficiency η mean in power calculation?
The efficiency η is the ratio between useful power and absorbed power. For a motor, it links the absorbed electrical power to the mechanical power available at the shaft. Use the manufacturer's value corresponding to the operating regime; a generic value based on the motor's age does not allow reliable sizing. Learn more: Measurement tools.
Anemometers and wind study
What is the purpose of an anemometer in a wind project?
To measure the average wind and gusts on site (6–12 months recommended) to size power and mast height. References: anemometers.
Anemometers
How to measure the wind before choosing a wind turbine?
Use an anemometer placed as close as possible to the planned height and location for the rotor. A single measurement is not enough: the wind varies according to seasons, time, terrain, and obstacles. Monitoring over several months, ideally covering the main seasons, allows estimating average speed, gusts, and turbulence. Avoid extrapolating a measurement taken on the ground or behind a building. Learn more: Measurement tools.
Production meters and monitoring
How to choose the right energy meter?
Adapt the rating to the inverter's max current (15/20/32 A, etc.). Prefer clear reading and simple installation: meters.
How to choose the right wattmeter for my installation?
Size by voltage/current range (e.g., 0–60 V, 200 A DC) and according to location (DC batteries side or AC grid side). Category: wattmeters & meters.
How to install an energy meter?
Entrust the installation to a qualified person; cut the power before intervention. Products: energy meters.
How to monitor the production of a 2000W kit in a river application?
Wind/hydro injection inverters do not always offer reliable monitoring via application. For precise and continuous measurement, install an energy meter on the 230 V side (AC LCD) dedicated to the hydro path. See our AC meters.
Meter: single-phase or three-phase?
Most homes are in 230 V single-phase. The 230/400 V three-phase is mainly for more powerful installations or certain specific uses. Learn more: Electric meter.
Is there an app to monitor the production of my 700W kit?
Depending on the models, the micro-inverter offers Wi-Fi/Ethernet monitoring (portal/app). If not, add an energy meter on the AC side. Check the kit's datasheet for included connectivity. Options: 230 V solar inverters and LCD meters.
Should the 230V wind kit be connected directly to the electric meter?
The connection is not made directly on the meter terminals. The inverter connects to the electrical installation according to the kit's planned diagram, with an appropriate circuit and protections. Plug connection is only possible if it is planned and authorized for the configuration. Have the connection and procedures checked by an electrician and the network manager. Learn more: Electric meter.
Solar + wind hybrid: what production monitoring to estimate the energy actually sent to the water heater?
To measure the wind path production, use a compatible meter placed on this path. To measure the energy actually consumed by the water heater, its own circuit must be measured. These two measurements alone are not enough to attribute all the tank's energy to wind or solar when the network supplements the supply. Have the meter locations validated by an electrician. Useful links: AC meters.
Is the Storage MPPT 500-600W (12V) inverter for wind turbines compatible with the Linky meter?
The presence of a Linky is not enough to confirm the inverter's compatibility. Check that the exact reference is planned for your network, that its anti-islanding functions and compliance are documented, and that the connection procedures are carried out. Also identify its authorized input source: battery or wind generator depending on the model; the name "MPPT" does not allow deduction. Learn more: Electric meter.
Where to install the energy meter?
Between the inverter and the network protection (circuit breaker/differential). Basic diagrams: connection diagrams.
Where to install a MID sub-meter to measure the production of a wind inverter?
The MID sub-meter is installed on the 230 V output side of the inverter, on the dedicated line connecting the inverter to the electrical installation's connection point. It thus measures the energy actually transmitted on the home side. The exact positioning, wiring direction, and protections must comply with the meter's manual and be validated by a local electrician. Learn more: Electric meter.
Where to find electric meters and production monitoring?
Consult the dedicated section here: Electric meters.
Why install a mechanical energy meter?
To read production even when off and verify performance. Available models: energy meters.
Which regulator do you recommend for a 24V generator (non-wind application)?
Regulation must be chosen according to the exact generator, its output type, voltage and speed range, the load to be powered, and continuous use conditions. A hybrid wind controller is not automatically suitable for any mechanically driven generator. Also check the braking or load shedding and thermal dissipation required before selecting a reference. Useful links: hybrid MPPT regulation – intelligent management.
What type of generator and speed are suitable for powering the 2000W inverter in a river application?
A three-phase synchronous generator (3 AC wires) is needed, whose voltage/frequency remain within the inverter's input window. Adjust the speed (rpm) with a belt/pulley multiplier if necessary to reach the nominal range. Mechanical adaptation accessories: pulleys & multipliers.
What wattmeter and circuit breaker should be planned for a 48V / 2000W three-phase wind turbine?
Distinguish the variable three-phase of the generator from the domestic network at the inverter output. To measure the injected production, choose an AC meter suitable for the system's 230 V single-phase or 400 V three-phase output. Protections on the generator side and network side are sized separately according to manuals and currents; have their type and rating validated by an electrician. Useful links: AC meters.
"Bulb" output from a regulator directly on the 230V domestic meter: compatible?
No. The outputs marked "bulb" on a regulator are low voltage DC outputs (12/24 V) intended to power small loads (12/24 V lighting, small pumps, etc.). They should never be connected to the meter or the 230 V network. For injection into the domestic network, use a special wind injection inverter: Wind inverters 230 V. Regulator sheet: Hybrid MPPT controller. Final compatibility must be checked on the exact references: nominal voltage, input or output type, admissible power, regulation, and protections.
My meter only indicates 1.3kWh in two years: is the measurement reliable?
A very low value may result from truly limited production, an unsuitable meter, incorrect wiring direction, or a reset. It is not sufficient to conclude without verification. Check the type of meter, its connection, the instantaneous power on the inverter side, and compare with a suitable measuring device. No "normal" production level can be deduced without knowing the wind and the installation. Learn more: Electric meter.
Production meters
How to monitor the production of a wind turbine installation?
In self-consumption, the most reliable measurement is generally a dedicated AC energy meter on the 230V or 400V output of the inverter. The instantaneous display of the inverter can complement this monitoring. In battery charging, use the regulator's measurements and, if necessary, a battery controller. An existing solar application does not necessarily detect the added parallel wind production. Learn more: Electric meter.
Power curves
Do you have a power curve for the Vector 12V / 500W wind turbine?
When no power curve is published for this reference, Le Comptoir Éolien cannot provide an unpublished document or production value. The nominal power is not continuous production. To estimate the result on your site, use the information available on the product sheet and measure the wind at the future rotor level. Learn more: 12V 500W Vector 5 Blades Wind Turbine with External MPPT Regulation.
Electrical measurements
How to monitor the state of batteries on board a boat?
Install an energy monitor (voltage, current, Ah consumed) and record the values in the logbook. Meters/monitorings facilitate tracking.
How to test the three phases of a wind generator with a multimeter?
Tests on the output of a wind turbine must follow the safety and test procedure of its manual, with a device and a person suited to the possible voltages. Do not disconnect the generator while rotating and do not leave it without load if not authorized. When a phase-to-phase test is planned by the manufacturer, compare the three pairs under identical conditions; a discrepancy can guide the diagnosis without identifying the fault alone. Learn more: Measuring tools.
How to use a digital multimeter to check my installation?
Measure voltages, currents, and resistances, check polarities and continuities, and diagnose voltage drops/connections. Selection: multimeters.
Power curve (wind tunnel / laboratory) for the AeroSpiral 1000W 48V?
The available information is what is published on the product sheet. When no additional document is offered, Le Comptoir Éolien cannot provide an unpublished manual, curve, or certificate. Check the sheet of the concerned reference. Learn more: Vertical wind turbines AeroSpiral UWT – Silent alternative to the liam f1 wind turbine for 24V / 48V batteries.
Power curve for your wind turbines?
When no power curve is published for the concerned reference, Le Comptoir Éolien cannot provide an unpublished document or production value. The nominal power is not continuous production; assess the site based on wind measurements and the information available on the product sheet. Learn more: Info - wind turbines.
Need advice on a reference?
Specify the relevant references and the characteristics of your installation to customer service.