FAQ · Le Comptoir Éolien
Generators and transmission
Speed, voltage, mechanical drive, and hydraulic uses: key points to check for your project.

Choose a question to display its answer. The instructions in the model's manual should still be checked for your installation.
Help and resources
Do you have detailed technical data such as the number of poles or performance curves for your generators?
No, apart from the online datasheets. Performance heavily depends on the setup (wiring, regulation, temperature, load), making standard curves not very representative. Learn more: Wind generator.
Is it possible to obtain an outline plan for your generators?
We do not publish dimensioned outline plans beyond the dimensions indicated on the datasheets. Learn more: Wind generator.
Study / technical info on generators?
No. Our support is based on the product sheet and connection advice. We do not conduct personalized studies and we do not have additional manufacturer documentation. Learn more: Wind generator.
Detailed datasheets and efficiency/speed curves for generators 15476 and 15470?
We do not publish additional rpm ↔ torque/efficiency curves. The power difference (≈200 W) comes from internal elements (winding, magnets, losses). The available information is on the online datasheets. Category: permanent magnet generators.
48V generators compatible with Victron?
A 48 V generator does not connect directly to a Victron solar input. Integration on the battery side can be studied with suitable wind regulation, provided the charge thresholds, currents, battery, BMS, and protections are checked. Confirm the architecture for exact references; the common nominal voltage is not enough. Learn more: 48v wind generators.
Pulleys for generators/alternators?
Check the dedicated section here: Pulleys for generators.
Why don't you provide performance curves for your alternators?
Lab results (often no-load) do not reflect real conditions (temperature, cables, regulation, load). We publish useful and representative data on the datasheets. Learn more: Wind generator.
Do you offer regulation allowing a hydrogenerator to run freely when the batteries are full?
We do not offer a validated setup allowing a hydrogenerator to automatically switch to free rotation when the batteries are full, while stopping or disconnecting its regulation. Available regulators generally use braking or load shedding to manage excess energy. For use on a sailboat shaft line, a system specifically designed for hydrogeneration and validated by its manufacturer is required. Learn more: Hybrid wind regulators.
Can I stiffen the springs or disable the safety to get more power?
No. Stiffening the springs or neutralizing the safety system can damage the generator and inverter and void the warranty. The device protects the machine during gusts. To improve production, rather optimize the installation (height/clearance/guys) and wiring: Installation advice • Section calculation. Final compatibility must be checked on exact references: nominal voltage, type of input or output, admissible power, regulation, and protections.
Are your pulleys compatible without modification?
Generally, no: the available pulleys often require adaptation (machining, bore adjustment, etc.) depending on the alternator. Learn more: Pulleys for wind generators.
Are your pulleys resistant to outdoor weather conditions?
Our aluminum pulleys are suitable for outdoor use (surface treatments depending on the model). Protect printed/PLA versions from UV and heat; prefer aluminum for durable performance. See the range: pulleys.
12/24/48V Generators
Do you offer a brushless generator and inverter set for grid self-consumption?
Check the currently published sets and components. A brushless or permanent magnet generator cannot be paired with just any inverter: the voltage, frequency or speed, current, output type, and input curve must match. Prefer an explicitly validated kit. For a generator outside the range, ask the manufacturer for compatible electronics and have the grid connection validated. Learn more: ERDF wind kits self-consumption 230V/230V.
Which 24V generator should I choose for a mechanical application requiring about 600W continuous regulated power?
A nominal power alone is not enough to guarantee 600W continuous. You need to know the rotational speed, available torque, voltage-power curve, cooling, and the generator's sustainable operating mode. Le Comptoir Éolien does not perform this personalized sizing. Select a 24V generator whose published data covers the operating point, then have the regulator, protections, and thermal margin validated by a professional. Learn more: 24v wind generators.
Alternative if my 48V generator/wind turbine is more powerful than your inverters?
Do not distribute the output of the same generator over multiple inverters unless this architecture is explicitly provided by their manufacturers. A common nominal power or voltage does not guarantee compatibility. For a more powerful generator, have a conversion chain and protections selected that are validated for its actual range of voltage, current, and speed. Learn more: Info - wind turbines.
Looking for a 12V generator driven by a 12V DC motor: do you have this product?
Yes, check our 12V mechanically driven generators (torque/rpm to be respected). Ensure your motor can provide the required torque at the useful speed. Category: generators.
How to choose the power (350 / 800 / 2000W) of the generator for my channel?
The choice depends on the flow rate (Q), the head height (H), the efficiency of the wheel, and the available rotational speed/torque. Without measurements (Q, H, rpm), proper sizing cannot be done. Have the flow rate and head measured (ideally over several weeks) then choose a kit whose nominal speed and power match what your wheel can provide. Learn more: Wind generator.
How to choose the voltage 12V, 24V, or 48V of a wind turbine or generator?
12V for small uses; 24–48V for housing (less intensity and losses, simplified wiring). Pair the generator with a compatible regulator and the right chain (batteries or grid inverter). Learn more: 48v horizontal wind turbines.
How to check that my 48V generator is working properly?
The control depends on the generator, rectification, and regulator. An AC voltage measured between two conductors should not be directly equated to the 48V DC park voltage. Follow the values and procedure in the manual, without a generic threshold. Have measurements taken between pairs of conductors by a qualified person and do not disconnect a rotating generator for an impromptu test. Learn more: 48v wind generators.
Which generator to choose for a micro wind turbine driven by a VMC airflow at 37 km/h?
We do not have a standard recommendation for this application (aerodynamics in duct, low useful section, losses). An electrotechnical study is necessary to assess the available power, transmission ratio, and generator. For information: permanent magnet generators and pulleys/multipliers.
Conversion from a piston pump to generator + 24V pump: do you offer a conversion kit?
We do not have a turnkey conversion kit. However, you can choose a generator suitable for the torque/speed of your mechanics, then select a 24V pump separately. Category to browse: permanent magnet generators.
Directly the generator on a 5V USB port: compatible?
No. A USB input expects a regulated 5V power supply adapted to the device's protocol. A generator produces a variable voltage: a regulation, protection, and possibly storage chain explicitly sized for it is needed. A simple adapter or any 12V regulator does not guarantee this compatibility. Resources: 12V micro-regulator.
400W "free energy" generator at 83 rpm: do you sell the parts?
No, we do not offer perpetual motion systems. A generator always needs a mechanical source (wind, water, thermal/electric engine). However, we offer permanent magnet generators and drive accessories for real projects (wind, micro-hydro): generators and pulleys/multipliers.
30kW generator already purchased: what to do?
Contact the seller/manufacturer to obtain the exact reference of the compatible inverter/conversion cabinet, then have the connection validated and carried out by a qualified electrician (phase balancing, protections, safety). Learn more: Wind generator.
Generator ref. 15373: complete specifications?
We do not have detailed rpm ↔ torque curves beyond the product sheet. Refer to the sheet and, if necessary, to the 230 V wind inverter range for an injection setup.
Standalone generator for HYE 3000W wind turbine (grid-connected)?
No, we do not have this generator (model discontinued by the manufacturer). Learn more: Wind generator.
12V / 300W generator: which MPPT / controller?
Use a suitable 12 V wind regulator with braking or load shedding management. Learn more: 12v wind generators.
12V / 300W generator: max speed?
The allowable speed depends on the exact model. Without detailed manufacturer data, avoid overspeeding. Learn more: 12v wind generators.
48V / 3800W standalone generator?
No. A generator is not standalone: it must be mechanically driven by a suitable source. Learn more: 48v wind generators.
Hydro turbine at 136 rpm and ~15 N·m: which generator?
At 136 rpm and 15 N·m, the available mechanical power is about 214 W, before transmission and conversion losses. The electrical power will therefore be lower. A multiplier can adapt the speed to a generator, but it reduces the available torque and does not increase the power. Choose a model whose data covers the regime, torque, and voltage actually available. Resources: generators · pulleys/multipliers.
Low-speed hydro turbine (50–250 rpm): which alternator do you recommend and do you have a speed/power chart?
Aim for a low-speed generator 200–400 W (e.g., 400 W families) with a possible multiplier if the voltage remains insufficient at low rpm. We do not publish detailed curves. See generators and pulleys/multipliers.
I need info on the brushless generator ref. 15090 in terms of speed (rpm)?
We do not have a detailed rpm → power curve for ref. 15090. As an indication, production often starts around ~100 rpm and the useful range is rather between ~300 and 600 rpm depending on the setup and load. To adapt the speed, a set of pulleys/multiplier may be necessary. See our categories: permanent magnet generators and pulleys & multipliers.
Kit 24V → 230V 500W: generator shaft diameter?
Shaft Ø 17 mm. Details: ref. 13021.
Is the 48V 500W generator (ref. 10216) still available for an Air Breeze?
Check our 48 V generators section; availability and compatibility depend on your Air Breeze version (12/24/48 V and internal regulation). Be sure to verify the nominal voltage and electronics before purchase: 48 V generators.
What does the "1000W" power of a generator correspond to?
Often to a max (peak) power achievable at a certain speed and with good cooling. Continuously 24/7, the usable power is often much lower (order of magnitude varies according to speed/load/temperature). Learn more: Wind turbine generator.
Is the generator waterproof and suitable for use in a humid environment / hydro turbine?
Moisture suitability depends on the protection index and the conditions published for the exact reference. Do not consider a generator as waterproof or submersible without explicit indication. For a hydraulic application, validate the casing, shaft passages, connections, ventilation, and anti-corrosion protection, without enclosing the equipment in a volume causing overheating. Learn more: Pelton turbine blade.
My 48V generator (1kW) only produces ~180W: is this abnormal?
Not necessarily. The power mainly depends on the available mechanical power (flow/torque/speed), the stability of rotation, and the generator ↔ inverter match. Learn more: 48v wind turbine generators.
Models of low-speed wind turbines or generators other than those presented on your site?
No, only the references displayed online are available. Browse: PMG Generators.
Where is the generator located in a wind turbine?
Horizontal: in the nacelle, at the top of the mast, behind the blades. Vertical: often at the base of the mast (easy access, mass on the ground). Learn more: Vertical wind turbines.
Can a generator be operated continuously at full power?
Use the continuous power and operating conditions published for the exact reference, considering cooling, speed, torque, and ambient temperature. A maximum or nominal power does not guarantee permanent operation at this value. Without continuous service data, no universal percentage allows validating the sustainable power. Learn more: Wind turbine generator.
Why should the generator be oversized compared to its nominal power?
Distinguish between nominal, maximum, and continuous power according to the manufacturer's definitions. The choice for sustainable operation depends on the regime, torque, losses, and cooling. There is no general rule allowing only 25 or 30% of the nominal: use the model's continuous service data and validate the thermal margin. Learn more: Wind turbine generator.
Why isn't the 48V 3800W generator offered in your self-consumption kits?
This generator is mainly oriented towards battery charging in isolated sites, with a suitable wind regulator, and towards machines intended for very windy sites, like the PRO-HISPER. It is not integrated or validated in our self-consumption kits with a 2000 W grid inverter. A common nominal voltage of 48 V is not enough to ensure compatibility between a generator and an inverter. Learn more: 48V 3800w permanent magnet generator at low RPM.
Why does the power decrease when the generator heats up?
The more the generator heats up, the more the losses increase and the usable power may decrease. If the speed is not high/stable enough, one may also remain far from the announced maximum power. Learn more: Wind generator.
Why is the output voltage of my generator not constant?
It's normal: the voltage varies with the rotational speed (the faster it spins, the higher the voltage rises). Learn more: Wind generator.
Why not offer more powerful generator kits (3000 / 4000 / 5000W)?
Beyond 2000W, the interest often becomes limited (constraints of torque, heating, efficiency, and durability), except for very specific custom solutions. Learn more: Wind generator.
Why is a 30kW generator not compatible with your wind kits?
Because the power is too high for our inverters/kits (designed for small powers in 12/24/48V and up to ~6 kW in three-phase). A 30 kW requires specific conversion and connection. The final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections. Learn more: ERDF self-consumption wind kits 380v/400v.
Can I mount a 48V 3800W generator on the support of my current generator?
Mechanical compatibility is not confirmed. An identical voltage does not mean that both generators use the same support. You need to compare the dimensions, the diameter and threading of the shaft, the plate or mounting points, the hub, the weight, as well as the mechanical forces supported by the assembly. Without explicitly indicated compatibility on the product sheet, do not consider the supports as interchangeable. Any adaptation must be mechanically validated before assembly. The final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections. Learn more: 48V 3800w permanent magnet generator with low RPM.
Can I use a permanent magnet generator as a hydrogenerator to charge LiFePO4 batteries?
It is conceivable only with a generator adapted to the available torque and speed, as well as a regulator designed for this generator and for battery charging. Do not directly connect a three-phase generator to a solar MPPT. You need to manage rectification, charging voltages, the BMS, the admissible current, and excess energy when the batteries are full. A mechanical adaptation on the drive line must also be validated for alignment, bearings, speed, and transmitted forces. The final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections. Learn more: Wind generator.
What is a residential wind generator?
The generator (PMG) converts mechanical energy into electricity (low voltage three-phase AC). It largely determines the nominal voltage (12/24/48 V) and power. Learn more: ERDF self-consumption wind kits 380v/400v.
What is the operating principle of a wind generator?
The rotor drives the generator, which converts mechanical power into electricity. Its voltage varies notably with speed; the current and power delivered also depend on the load and system limits. The output is then adapted by regulation for batteries or by an explicitly compatible inverter for grid injection. Resources: permanent magnet generators.
What simple alternative if I want to change the generator without too much risk (staying at 48V)?
A common good compromise is a 48V 800W generator (ref. 15278): See the product
What is the difference between an alternator and a dynamo?
The alternator produces AC (easy to transport/rectify), the dynamo DC. In small wind power, the alternator (PMG) is preferred for efficiency and conversion simplicity. Learn more: Wind generator.
Which three-phase permanent magnet generator to choose for a 2 to 3kW prototype between 800 and 1400 rpm?
The 48 V / 2000 W permanent magnet generator, reference 10604, can be a base to study for this type of prototype. Before purchase, compare the available curves with your actual speed, mechanical torque, expected voltage, load, and cooling. The reference should not be considered as a guarantee to reach 2 to 3 kW over the entire range of 800 to 1400 rpm. Learn more: 48V 2000w permanent magnet generator.
What continuous power to recommend to preserve the generator (ref. 13023)?
The continuous sustainable power of reference 13023 must be verified in its operating data, with the regime, torque, temperature, and planned cooling. Do not deduce a guaranteed continuous value from the announced maximum power alone. Without sufficient published data, have the operating point validated before prolonged use. Learn more: Generator + inverter kit 48V 230V 2000W.
What generator power to choose for 600W continuous at 24V?
For 600W continuous electrical power at 24V, the mechanical source must provide more than 600W to cover losses. You need a generator whose continuous service data covers your speed, torque, cooling, and voltage under load. Do not use a generic 25% conversion of the rated power; validate the operating point and regulation. Learn more: 24v Wind Generators.
What are the dimensions (Ø, height) of the "vertical base 12V / 500W permanent magnet" generator?
Order of magnitude: Ø ≈ 20 cm, height ≈ 15 cm (depending on series). Refer to the model sheet for available dimensions. Category: generators.
Hydro and mechanical drive
Explore the key aspects of a hydropower project: water resources, generator and transmission.
How to calculate the theoretical daily energy of a 48V / 230V 2000W generator kit?
The theoretical energy is calculated by actually maintained average power × duration. For example, a measured and stable power over several hours can be converted into Wh or kWh using this formula. The 2000W power is a nominal value and should not be used as a guaranteed continuous power. In hydro or mechanical drive, the result depends on torque, speed, cooling, losses, and the inverter's input window. Learn more: 48V 230V 2000W Generator Kit + Inverter.
What voltage to choose for a generator driven by a water wheel?
The 12V, 24V, or 48V voltage does not create additional power: production depends primarily on the torque and speed provided by the wheel. The choice must match the regulator, batteries, or inverter used. At equal power, 48V generally reduces current and losses over long connections. However, check the generator's speed and voltage range as well as the conversion electronics. Learn more: Wind Generator.
How to choose the right blade for my Pelton turbine?
Consider the wheel diameter, the number of buckets, the flow rate, and the head (H, Q) to aim for a specific speed compatible with your generator. Compare models and their dimensions: Pelton Blades.
How to maintain a Pelton turbine blade?
Periodic inspection of the buckets (erosion, deposits), cleaning of encrustations, and checking for imbalance. Preventive maintenance maintains efficiency and limits wear on the shaft/bearings. Parts and buckets: blades & buckets.
How to install a Pelton blade on a hydraulic turbine?
Mount the wheel on the shaft (key/nut or tapered hub), align the injector(s), and check the runout. Tighten to torque and check for leaks. Refer to model dimensions: Pelton Blades.
What does the actual production (paddle wheel / mill) depend on?
Mainly on the regularity (water flow/speed), and the available torque to drive the generator over time. Learn more: Blade for Pelton turbine.
Sizing (flow/head study, turbine choice) for a micro-hydro?
No, we do not have a design office for the hydraulic part (flow, head, pressure loss, wheel choice). It is preferable to consult a local professional to validate feasibility and obtain Q (flow) and H (head), then choose the corresponding kit. Learn more: Blade for Pelton turbine.
Micro-hydro (canal) ~500–2000W: what equipment to produce 230V for self-consumption without battery?
For direct injection into the 230V grid, choose a generator kit + inverter (specific for hydro/wind). Ready-to-use examples: • 350W Generator Kit + 230V Inverter • 48V 800W Generator Kit + 230V Inverter • 48V 2000W Generator Kit + 230V Inverter These kits rectify and stabilize the turbine's energy and then inject it in the 230V format compliant with the grid.
Micro-hydro 48V / 3.8kW: is there a solution for three-phase 400V injection?
Yes, you can opt for an inverter dedicated to 380/400 V networks. Check the input voltage/frequency compatibility on the generator side and the required protections (anti-islanding, disconnection). Browse the range: wind/hydro inverters 380/400 V.
Home micro-hydro (water wheel + low-speed generator) to charge a Bluetti station: is it feasible?
Directly connecting a generator to a Bluetti is rarely compatible (DC ranges and internal limits). Safer solution: generator → 12/24 V regulator → batteries → 230 V converter → charge the Bluetti with its adapter. See regulators.
Can only the buckets of a Pelton wheel be replaced?
Yes, replacement buckets are offered to replace only the damaged ones. Check the wheel diameter and the center distance before ordering: Pelton buckets. Final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections.
Do you offer a three-phase asynchronous generator of 3.5 to 4kW and a variable speed drive for a water mill?
No. We do not offer a three-phase asynchronous generator 750 or 1500 rpm of 3.5 to 4 kW, nor an industrial frequency converter validated to stabilize a 50 Hz output from a variable hydraulic drive. Our range is mainly oriented towards permanent magnet generators in 12 V, 24 V, or 48 V and towards small wind or hydromechanical installations. The feasibility of a water mill depends on the flow rate, head height, torque, runner speed, transmission ratio, and mechanical losses. Have these elements validated by a design office or a professional specialized in hydroelectricity. Learn more: Wind generator.
What is a Pelton turbine and what is it used for?
A Pelton turbine is an impulse hydraulic turbine: one or more jets strike the buckets of a wheel and transform the water's energy into mechanical rotation. A generator can then convert this rotation into electricity. The choice depends notably on the head height, flow rate, and speed suitable for the generator. Resources: Pelton wheels.
Which generator to choose for a system powered by a paddle wheel or a stream?
Choose the generator according to the mechanical power, speed, and torque actually available at the shaft. The flow rate, head height, and turbine efficiency allow estimating the exploitable hydraulic power, then the transmission determines the regime and torque to the generator. Validation of these measurements is necessary before choosing the model and electronics. Resources: PMG Generators · pulleys · Pelton wheels.
Which generator do you recommend for a hydro plant between 500 and 750 rpm, with a power of 300 to 800W?
We offer the reference 15462 (generator kit + 230 V inverter) for this range, provided the pulley ratio is adjusted to reach the generator's nominal speed and the inverter's input window. Measure the actual speed and adjust the multiplier if necessary. See low-speed generators and wind inverters 230 V.
What simple setup to charge a smartphone from a paddle wheel?
Recommended connection chain: Mini-generator → Micro-regulator 12 V → 12 V battery (buffer) → 12 V converter → 5 V USB → Phone. Consult our schematic diagrams for protections (fuse) and wiring.
What is the difference between a Pelton wheel with 16, 18, and 25 buckets?
The number of buckets is not enough to choose a Pelton wheel nor to guarantee better efficiency. Also compare the wheel diameter, jet diameter, bucket geometry, flow rate, head height, and generator speed. Use the manufacturer's prescriptions for the chosen wheel and injector combination. Resources: Pelton wheels.
If I switch from 48V to 24V or 12V, will I produce more (water wheel/mill/mechanical drive)?
No, changing voltage does not create more power: production mainly depends on the torque and speed provided by your drive (water wheel/mechanical), not on 12/24/48V. Learn more: Pelton turbine wheel.
Are your permanent magnet generators suitable for a mill wheel?
A permanent magnet generator can be driven by a mill wheel if its speed, torque, mechanical power, and continuous operation are compatible. Adaptation with pulleys may be necessary. The system voltage and cable section must be chosen together, according to distance and current; 48 V is not sufficient to confirm compatibility. Resources: pulleys.
Are your Pelton blades compatible with all hydroelectric turbines?
Compatibility with a Pelton turbine is not universal. Check the diameter, bore, hub, mounting, permissible speed, and hydraulic characteristics of the model. If in doubt, send the references and dimensions to customer service. Resources: Customer service.
What equipment is needed to inject into a single-phase 230V network with a 48V / 3.8kW micro-hydro?
An installation of this power requires an inverter or a conversion cabinet explicitly compatible with the generator, its voltage, output type, speed range, and power. Direct connection should not be assumed possible. Le Comptoir Éolien does not perform this personalized sizing. Have the possible rectification, regulation, load shedding, protections, anti-islanding, and connection validated by the manufacturer and a specialized electrician. Learn more: Wind network injection inverters 230V.
Is a buffer battery necessary for a small 12V hydro installation intended to charge a phone?
A buffer battery is generally recommended to stabilize the voltage and absorb variations in generator speed. Direct connection to a USB port is not suitable. Provide compatible rectification and regulation, a 12V battery of appropriate capacity, a DC/DC converter to 5V, and a fuse close to the battery. The equipment must remain protected from water and splashes. Learn more: Wind generator.
Rectification and diode bridges
What is the purpose of a rectifier diode bridge on a three-phase wind generator?
A diode bridge converts the three-phase AC output of a generator into DC current. It may be necessary before regulation or battery charging when this function is not already integrated into the device used. The bridge must be sized for the system's voltage and current. To charge a battery, rectification alone is not enough: a wind regulation and appropriate load shedding device are also required. Learn more: Rectifier diode bridge.
Three-phase output and rectification
Why are the 3 wires of the generator the same color?
A three-wire generator generally delivers three-phase AC: the conductors correspond to the U, V, and W phases and have no positive or negative polarity. The connection must follow the instructions of the compatible regulator, rectifier, or inverter. Color alone does not identify a conductor's function. Learn more: Wind generator.
Transmission and speed
Does the AIR-SIDE 2000W 48V wind kit ref. 15717 have gears?
Check the mechanical architecture published on the reference 15717 datasheet. If the datasheet indicates a direct-drive generator, no intermediate gears are used; this characteristic should not be inferred from another model. Do not modify the transmission without the manufacturer's validation, as this may alter speed, torque, safety, and warranty. Learn more: Domestic wind kit Air-Side 2000W 48V.
How to choose the right pulley for my wind generator?
Check the bore/shaft, belt profile (SPZ/SPA/SPB...), diameter (gear ratio), and material. Aluminum combines lightness and strength; prefer conical hubs (taper-lock) for reliable mounting. See: pulleys.
How to install a pulley on a wind generator?
Mount on a clean/degreased shaft, align with the belt, tighten the locking screws (or taper-lock sleeve) to the torque, and check the runout. Recheck the belt tension after the first few hours. Help: pulleys.
Vertical Windside 12V 500W wind turbine: do you have curves (I / P vs RPM)?
No, no curves available. Performance depends on the site and regulation; refer to the product sheet. Learn more: Vertical wind turbines 12v.
48V / 3800W Generator: output torque?
The torque depends on the speed, load, and application. Without detailed manufacturer data, it's not possible to provide a universal value. Learn more: 48v Wind Generators.
I've heard about a motorized system (belt) to boost the wind turbine when the wind is weak. Do you have that?
We do not offer a motorized system designed to artificially increase a wind turbine's output. Driving the generator with a motor consumes energy and adds mechanical and electrical losses. To improve wind production, consider examining the wind resource, location, height, and cable sizing. Resources: masts · section calculation.
V-belt pulley ref. 15220 (Ø ext. 80 mm, bore 19 mm): compatible with SPB 17 mm belt?
Check the reference 15220 datasheet for the intended groove profile, its width, angle, and depth, as well as the bore and diameter. The 17 mm width alone is not enough to confirm compatibility with an SPB belt. Electrical criteria do not concern this mechanical pairing. Resources: pulleys.
Why use a pulley for a wind generator?
A belt and pulley transmission allows adapting the rotor speed to that of the generator. The chosen ratio modifies the available speed and torque, with transmission losses. It must be calculated according to the generator curves and permissible mechanical forces; it does not guarantee an increase in efficiency. Resources: pulleys for generators.
What torque is needed to supply a 48V 2000W generator to produce 1500W?
There is no single value without knowing the actual rotational speed. The required mechanical torque directly depends on power and speed according to the relation: torque = power ÷ angular speed. To obtain 1500 W electrical, you must also consider the generator's efficiency, load, voltage, temperature, and cooling. The mechanical torque to be supplied will therefore be higher than the theoretical calculation based solely on 1500 W. As the detailed torque/speed curve is not provided by the manufacturer, we cannot guarantee a precise torque to reach 1500 W. Consult the available curves on the product sheet and have the mechanical sizing validated according to the expected speed. Learn more: 48V 2000w Permanent Magnet Generator at Low RPM.
What is the starting torque of the 48V 2000W permanent magnet generator at low speed?
The exact value of the starting torque is not provided for this reference. The generator is designed to operate at low rotational speed, but the term "low starting torque" does not constitute a guaranteed numerical value. Before purchasing, check the curves and characteristics published on the product sheet. For motor, hydraulic turbine, wheel, or mechanical transmission drive, also allow sufficient margin to overcome friction, inertia, and transmission losses. Learn more: 48V 2000w Permanent Magnet Generator at Low RPM.
Which belt to use with the pulleys?
Use V-belts compatible with the groove profile (SPZ/SPA/SPB…). Respect the pretension and alignment to limit wear and losses. Refer to the pulley datasheets: pulleys.
What is the difference between an aluminum pulley and a PLA pulley?
Aluminum: strong mechanical resistance, good weather resistance, durable use. PLA (3D printing): reserved for sheltered models/tests (UV/heat sensitivity and lower resistance). For a real installation, prefer aluminum (or treated steel): aluminum pulleys.
Torque and power table for your permanent magnet generators?
No, these values vary greatly depending on the load, regulation, and setup. Refer to the general specifications on the online datasheets. Learn more: Wind Generator.
What can a 24V / 500W generator produce when driven only at 100 or 200 rpm?
The answer depends on the voltage-speed curve of the reference. At a speed well below the nominal point, the voltage and power may be insufficient to charge a 24V park or power the intended electronics. Measure the open-circuit voltage and then under load with caution and compare to published data. The 500W power cannot be extrapolated to 100 or 200 rpm without a curve. Learn more: 24v Wind Generators.
Do wind turbines use a direct-drive generator or a geared system?
The architecture depends on the model. Many small permanent magnet wind turbines are direct-drive, while other machines or mechanical adaptations may use a transmission. Check the datasheet and technical views of the specific reference; do not generalize an architecture to the entire range. Learn more: Wind turbine generator.
What rotation speed is required to operate a 24V / 500W permanent magnet generator?
The required speed depends on the reference, the voltage to be reached under load, the available torque, and the generator curve. The mention 24V / 500W does not alone define a universal regime. Consult the voltage-speed or power-speed curve of the exact model. In the absence of published data, measure progressively without exceeding mechanical, electrical, and thermal limits. Learn more: 24v wind turbine generators.
Three-phase AC
Is there a polarity or order to follow on the three wires of a generator?
On the three-phase AC output, there is no positive or negative polarity. For a diode bridge or many wind regulators, the phase order generally does not prevent rectification. However, follow the instructions when the electronics identify the U, V, and W terminals or impose a specific order. Grounding concerns the metallic parts and the designated terminal, not one of the phases. Learn more: Wiring diagrams - solar and wind.
How to connect a three-wire three-phase wind turbine generator?
Connect the three phases only to the three-phase input of a wind regulator, a diode bridge, or an inverter explicitly designed for this generator. The equipment must accept the possible voltage, current, and power. Do not connect the three wires to a PV input, a battery, or an inverter not designed for wind. Follow the diagram of the specific reference. Learn more: Wiring diagrams - solar and wind.
Why does a wind turbine generator have three wires?
A three-wire generator generally delivers three-phase AC. The three conductors correspond to the phases; they do not constitute a positive, a negative, and a ground. Conversion to direct current or the grid is performed by a diode bridge, a wind regulator, or an explicitly compatible inverter, depending on the architecture. Learn more: Wind turbine generator.
Need advice on a reference?
Specify the relevant references and the characteristics of your installation to customer service.